Leakage Reactance
Leakage reactance
In a certain 3-phase induction motor, the leakage reactance is five times the resistance for both primary and secondary windings. The primary impedance is identical with the referred secondary impedance. The slip at full load is 3%. It is desired to limit the starting current to three times the full-load current.
How do you find the leakage reactance?
Measurement of leakage reactance in power transformer This voltage divided by the rated winding voltage, then multiplying by 100 results to percent reactance or %X. So leakage reactance is termed as, %reactance= (reactance voltage drop/winding voltage)/100.
What is resistance and leakage reactance in transformer?
The resistance of Transformer means the resistance of primary and secondary winding of the transformer. And leakage reactance of Transformer means there is some magnetic leaking in the both of the windings that should be equal to inductive coils connected in both primary & secondary winding which is shown in fig-1.
What is meant by leakage inductance?
Leakage inductance in a transformer is an inductive component that results from the imperfect magnetic linking of one winding to another. In an ideal transformer, 100% of the energy is magnetically coupled from the primary to the secondary windings.
What is meant by leakage resistance?
Leakage resistance is the dominant static circuit-board effect. Contamination of the PCB surface by flux residues, deposited salts, and other debris can create leakage paths between circuit nodes. Even on well-cleaned boards, it is not unusual to find 10 nA or more of leakage to nearby nodes from 15 V supply rails.
Why it is called reactance?
Reactance, denoted X, is a form of opposition that electronic components exhibit to the passage of alternating current (alternating current) because of capacitance or inductance. In some respects, reactance is like an AC counterpart of DC (direct current) resistance.
What is leakage factor formula?
The ratio of the total flux produced to the useful flux set up in the air gap of the magnetic circuit is called leakage coefficient or leakage factor. It is denoted by (λ). λ = ϕ a ϕ g.
What is leakage current formula?
Using the formula I = 377VC, find the leakage current I (in amps) by multiplying the voltage that your hipot test is conducted at (V) by the capacitance you measured between line and ground (C), and multiplying that product by 377. This will give you the anticipated leakage current I (in amps).
What is armature leakage reactance?
HE ARMATURE leakage may be defined as the reactance due to the difference between the total flux produced by an armature current and the flux in the airgap produced by the same armature current. There are a number of components of stator leakage.
What are the two types of reactance?
Reactance is of two types: inductive and capacitive.
What is reactance formula?
The inductive reactance for an inductor with inductance L connected in the circuit along with AC power supply is given as: XL = 2πfL. Where, XL is the inductive reactance. L is the inductance of the inductor.
What is XL and XC in impedance?
Xc = Capacitive Reactance, in Ohms. • Xl = Inductive Reactance, in Ohms. • R = Resistance, in Ohms.
What is the unit of leakage?
The leak test industry in the U.S. has standardized on stating leak rates in units of “scc/m” or “scc/s” (atm cc/s) – standard cubic centimeters per minute or second. European industry uses “Pa-m3 /s” or “mbarl/s.” These are the SI gas leakage rate units defined in the Nondestructive Testing Handbook, Second Edition.
What causes leakage inductance?
Leakage inductance is an inductive component present in a transformer that results from the imperfect magnetic linking of one winding to another.
What is meant by leakage voltage?
In electronics, leakage is the gradual transfer of electrical energy across a boundary normally viewed as insulating, such as the spontaneous discharge of a charged capacitor, magnetic coupling of a transformer with other components, or flow of current across a transistor in the "off" state or a reverse-polarized diode
How is leakage measured?
The leakage current is measured by applying a fixed, high voltage DC and by measuring the leakage current flowing through the shunt. The high voltage DC is generated using an onboard power supply based on a flyback topology, which takes a wide range of DC input voltage from 150-V DC to 800-V DC.
What are the types of leakage?
Types of Leaks
- Real leak. When a pressure barrier fails to contain or isolate a system fluid from the surrounding environment (result of cracks or gaps between sealing surfaces or permeation through seal materials).
- Virtual leak.
- Permeation.
What is leakage current value?
The leakage current capability is generally defined in terms of the maximum voltage (or electric field which is voltage per unit thickness of the dielectric) that a dielectric can sustain without leading to runaway currents (usually defined as a given current per unit area, e.g., 1×10−6 A cm−2).
What is reactance used for?
The reactance is used to compute this change in phase and magnitude of the current and voltage waveforms. When an alternating current passes through the element, the energy is stored in the element that contains reactance. The energy is released in the form of an electric field or magnetic field.
What is the unit of reactance?
Reactance is mathematically symbolized by the letter “X” and is measured in the unit of ohms (Ω).